BALDOR MOTOR ELECTRIC tipe Explosion Proof Motor
Jenis
motor tahan ledakan atau explosion merek Baldor ini sangat pas buat berbagai
aplikasi yang menyangkut motor. Khususnya fume atau debu yang berbahaya ada di
sekitar area di mana motor electric ini berada. Baldor motor electric jenis ini
tersedia dalam fase tiga atau fase tunggal berikut ratings.
Baldor electric motor tersedia dalam stok kami. mulai dari baldor motor electric jenis motor tahan explosion 1/4 HP hingga 300 HP.
Desain jenis motor electric ini tersedia dengan standar kaki mounted. C face
dengan base dan C face less base, 60 Hz and 50 Hz.
(see tech specs)
Lihat spec detail seputar mesin baldor electric di bawah ini :
ul and csa explosion-proof classifications
1. Hazardous Locations- Class I Group D locations are atmospheres containing elements such as Gasoline, Hexane, naptha, Benzine, Butane, Propane, Alcohol, Acethone, Benzol, Lacquer Solvent Vapors or Natural Gas.
Class II Group F & G locations are atmospheres containing dust such as (F) Carbon Black, coal or coke Dust, (G) Flour, Strach or Grain Dusts.
2. As required by Underwriters' Laboratories and Canadian Association, explosion-proof motors with Class II Group F & G approvals must have over temperature protection.
Explosion-Proof Motors rated 1 1/2 HP or less have internally mounted automatic thermal overloads when indicated by suffix "A". Caution shoulds be observed when applying these to machinery applications to prevent accidental injury when the thermal device authmatically resets and restarts the motor.
Explosion-Proof Motors rated 1 HP and larger without automatic thermal overloads have thermostats in the windings. These thermostats are pilot circuit devices to be connected to the magnetic starter circuit.
3. Temperature Ratings and code Numbers : Surface temperatures of Baldor Explosion-Proof Motors will not exceed the following UL and CSA maximums under fault conditions.
a. Class I Group D listings only. motors with Class B insulation will not exceed surface temperatures of 230 C (446 CF) equivalent to Code T2C. Motors with Class F insulation and 1.15 S.F. will not exceed surface temperatures of 260 C (500F) equivalent to Code T2B.
b Class II Group F & G listings only. Fractional HP motors in Baldor type 34 will not exceed suface temperature of 160 C (320 F) equivalent to Code T3C. Fractional HP motors in Baldor type 35 will not exceed suface temperature of 135 C (275 F) equivalent to Code T4 Motors 1HP and greater built in Baldor type 35. Frames 143T through 326T will not exceed surface temperatures of 160 C (320 F) equivalent to Code T4.
4. Not suitable for applications in temperatures below -25 C (-13 F)
5. All Explosin-Proof motors are supplied with Explosion-Proof UL and CSA approved conduit boxes as standard.
6. Baldor AC Induction Explosion Proof Motors are not approved for use on variable voltage or variable frequency controls (inverter or Vector Drives)